Global Infrastructure
We do not own data centers. Instead we partner with several outstanding local providers of data centers and infrastructure all across the world. This allows us to always be able to choose the best providers for our resellers, and our resellers are free to choose where they want to store their data. This is of great importance especially when it comes to compliance with local legislators et cetera.
The data centers consist of market-leading infrastructure regarding capacity, redundancy and security. Depending on the service, the data is backed up or replicated daily to at least one other geographical location.
Our global infrastructure also enable the possibilities with Web Scale. Web scale is crucial regarding cost and management effectiveness since it allows users to expand or increase the use of resources depending on their present need.
All this means that we can guarantee both technical and business redundancy as well as low latency no matter where your customers are located.
European Data Centers
IP-Only
IP-Only has data centers located in Sweden with high security and reliability in direct connection to its own fiber network.
Specifications
- Power 230V AC/48V DC
- Points for traffic exchange include Netnod’s interconnection hubs in Stockholm, Gothenburg, Malmo and Sundsvall, as well as the Internet Exchanges in several European cities and New York.
- 24-hour surveillance, fire and theft protection, fuel reserves, climate control
- DWDM/CWDM systems
- Fiber connection to IP-Only, Telia and GothNet as well as inhouse fiber trunk.
- The transmission network has a total installed capacity of 1.6 Terabit/s (1 600 Gigabit/s)
- Clean network structure in which the service platforms lie parallel directly over the WDM layer.
- Ethernet switches are directly connected over the WDM equipment
- 10 Gigabit/s Ethernet as a standard
Hetzner
Hetzner Online has several corporate high-capacity data centers in the Nuremberg area as well as a datacenter park in Falkenstein/Vogtl.
Specifications
- 40 GBit/s DE-CIX
- 30 GBit/s Noris Network
- 20 GBit/s Tiscali
- 20 GBit/s Deutsche Telekom
- 10 GBit/s LambdaNet, Global Crossing, Aixit, TeliaSonera, Level, Init7, KPN, N-IX, AMS-IX
- Energy efficient direct free cooling (DC 10)
- N+2 redundancy (DC 10)
- Cool Aisle Containment (DC 10)
- Monitoring of air temperature and server/distribution cabinets
- Modern early warning fire system with direct connection to the local fire department
- Special door locking system
- Redundant UPS facilities
- Diesel power generator
- Total area 6.850 square meter
U.S Data Centers
Internap
Internap provide scalable and rapidly deployed IT infrastructure managed in secure N+1 redundant environments.
Specifications
- Managed installation and 24/7 monitoring of the data center environment by on-site technicians
- High security, including on-site guards, biometric and/or electronic locks
- Redundant power and cooling infrastructure
- IP connectivity options provide easy access to major Internet backbones
- 6000kVA of power
- UPS batteries capable of supplying power to the facility for up to 12 minutes and six diesel generators on site that will enable the facility to operate without utility power.
- N+1 design that allows for the failure of some equipment and still enables service without interruption.
- Internap makes use of proprietary route-control platforms that overcome the limitations of traditional routing policies.
- The facility is connected to Internap’s Seattle fiber network ring at two different points.
Softlayer
Softlayer is one of the most advanced data center providers in the U.S offering scalable and top of the line IT-infrastructure. Ilait uses two of Softlayer's data centers in the U.S; Softlayer D.C and Softlayer Dallas.
SoftLayer Washington D.C and Dallas data centers are located in a private N+1 facility. The facilities includes three redundant TXU electrical grids, delivering diverse power to each quadrant of the building, three, on-site, 600-ton cooling towers, fully meeting N+1 cooling requirements.
Specifications
- 2000-9000 amps 480v input power
- 8 x 750/6 x 750 kVA UPS battery backup units
- 3 x 2/ 4 x 2mW diesel generators with on-site fuel storage
- Redundant Liebert 50-ton HVAC units
- Redundant Data-Aire 26-ton HVAC units
- Redundant 30-ton CRAC units
- FM-200 fire suppression system with VESDA
- Biometric security system
- Digital security video surveillance
- Pre-action dry pipe fire suppression